ï LOW PROFILE POWER SUPPLY
COLORS CONTINUOUS ICS Size (IN) Shipping
MODEL Gray Black Duty (Amps) (Amps) H x W x D Wt. (lbs.)
SL-11A ï ï 7 11 2 5/8 x 7 5/8 x 9 3/4 12
SL-11R ï ï 7 11 2 5/8 x 7 x 9 3/4 12
SL-11R-MC ï 7 11 5 3/8 x 7 1/4 x 9 3/4 13
SL-11R-GE ï 7 11 5 5/8 x 7 x 9 3/4 13
SL-11R-RA ï 7 11 4 3/4 x 7 x 9 3/4 13
SL-11R-EFJ ï 7 11 5 3/8 x 7 1/4 x 9 3/4 13
SL-11MG ï 7 11 5 1/4 x 7 1/16 x 9 3/4 13
SL-15R ï ï 12 15 2 3/8 x 7 x 9 3/4 13
SL-15R-GE ï 12 15 5 5/8 x 7 1/4 x 9 3/4 14
SL-15R-RA ï 12 15 4 3/4 x 7 1/4 x 9 3/4 14
SL-15R-EFJ ï 12 15 5 3/8 x 7 1/4 x 9 3/4 14
|
|||||||
|
|
ï POWER SUPPLIES WITH BUILT IN CIGARETTE RECEPTACLE
COLORS CONTINUOUS ICS Size (IN) Shipping
MODEL Gray Black Duty (Amps) (Amps) H x W x D Wt. (lbs.)
RS-4L ï 3 4 3 1/2 x 6 1/8 x 7 1/4 6
RS-5L ï 4 5 3 1/2 x 6 1/8 x 7 1/4 6
|
|||||||
![]() |
ï 19" RACK MOUNT POWER SUPPLIES
CONTINUOUS ICS Size (IN) Shipping
MODEL Duty (Amps) (Amps) H x W x D Wt. (lbs.)
RM-12A 9 12 5 1/4 x 19 x 8 1/4 16
RM-35A 25 35 5 1/4 x 19 x 12 1/2 38
RM-50A 37 50 5 1/4 x 19 x 12 1/2 50
RM-60A 50 55 5 1/4 x 19 x 12 1/2 60
ï Separate Volt and Amp Meters
RM-12M 9 12 5 1/4 x 19 x 8 1/4 16
RM-35M 25 35 5 1/4 x 19 x 12 1/2 38
RM-50M 37 50 5 1/4 x 19 x 12 1/2 50
RM-60M 50 55 5 1/4 x 19 x 12 1/2 60
|
|||||||
![]() |
COLORS CONTINUOUS ICS Size (IN) Shipping MODEL Gray Black Duty (Amps) (Amps) H x W x D Wt. (lbs.) RS-3A ï 2.5 3 3 x 4 3/4 x 5 3/4 4 RS-4A ï ï 3 4 3 3/4 x 6 1/2 x 9 5 RS-5A ï 4 5 3 1/2 x 6 1/8 x 7 1/4 7 RS-7A ï ï 5 7 3 3/4 x 6 1/2 x 9 9 RS-10A ï ï 7.5 10 4 x 7 1/2 x 10 3/4 11 RS-12A ï ï 9 12 4 1/2 x 8 x 9 13 RS-12B ï 9 12 4 x 7 1/2 x 10 3/4 13 RS-20A ï ï 16 20 5 x 9 x 10 1/2 18 RS-35A ï ï 25 35 5 x 11 x 11 27 RS-50A ï 37 50 6 x 13 3/4 x 11 46 RS-70A ï 57 70 6 x 13 3/4 x 12 1/8 48 |
|||||||
![]() |
CONTINUOUS ICS Size (IN) Shipping MODEL Duty (Amps) (Amps) H x W x D Wt. (lbs.) ï Switchable Volt and Amp Meter RS-12M 9 12 4 1/2 x 8 x 9 13 ï Separate Volt and Amp Meters RS-20M 16 20 5 x 9 x 10 1/2 18 RS-35M 25 35 5 x 11 x 11 27 RS-50M 37 50 6 x 13 3/4 x 11 46 RS-70M 57 70 6 x 13 3/4 x 12 1/8 48 |
|||||||
![]() |
ï Separate Volt and Amp Meters
ï Output Voltage adjustable from 12-15 volts
ï Current limit adjustable from 1.5 amp to full load
CONTINUOUS ICS* Size (IN) Shipping
MODEL Duty (Amps) (Amps) H x W x D Wt. (lbs.)
@13.8VDC @10VDC @5VDC @13.8VDC
VS-12M 9 5 2 12 4 1/2 x 8 x 9 13
VS-20M 16 9 4 20 5 x 9 x 10 1/2 20
VS-35M 25 15 7 35 5 x 11 x 11 29
VS-50M 37 22 10 50 6 x 13 3/4 x 11 46
VS-70M 57 34 16 70 6 x 13 3/4 x 12 1/8 48
ï Variable rack mount power supplies
VRM-35M 25 15 7 35 5 1/4 x 19 x 12 1/2 38
VRM-50M 37 22 10 50 5 1/4 x 19 x 12 1/2 50
* ICS - Intermittent Communication Service (50% Duty Cycle 5 min. on 5 min. off) |
|||||||
![]() |
ï Built in speaker
COLORS CONTINUOUS ICS Size (IN) Shipping
MODEL Gray Black Duty (Amps) (Amps) H x W x D Wt. (lbs.)
RS-7S ï ï 5 7 4 x 7 1/2 x 10 3/4 10
RS-10S ï ï 7.5 10 4 x 7 1/2 x 10 3/4 12
RS-12S ï ï 9 12 4 1/2 x 8 x 9 13
RS-20S ï ï 16 20 5 x 9 x 10 1/2 18
SL-11S ï ï 7 11 2 3/4 x 7 5/8 x 9 3/4 12
|
|||||||
![]() |
BATTERY BACKUP POWER SUPPLIES
The RS-10A, RS-12A, RS-20A, RM-35A/M, RM-50A/M, RM-10A, RM-12A/M & RM-60 are available with battery revert and trickle charge circuit with zero switch over time. (Battery not included.) To specify the backup circuit add BB after the model number. |
|||||||
![]() |
MODEL 1212 & 1212-18 Switching Regulated Converter
Designed for FM transceivers and other applications requiring 12-volt power
source converted from 12-volt positive ground battery. Regulated with pulse
width modulation at 20 KHz.
Input - 12 V DC (Positive ground only). Functional from - 11 V DC - 16 V DC.
Output + 13.8 V DC (Negative ground only).
1212 1212-18
Output Voltage 13.8 V DC (±.2V DC) 13.8 V DC (±.2V DC)
Line/Load Regulation 200mV 200mV
Ripple Noise 50mV RMS 50mV RMS
Current Continuous 6 Amp 14 Amp
Current (ICS) 7 Amp 18 Amp
Current Limit 8 Amp 19 Amp
Case 2 3/4(H) x 6(W) x 6(D) 2 3/4(H) x 6(W) x 12(D)
Shipping Weight 2 lbs. 4 lbs.
|
|||||||
![]() |
MODEL 2412 & 2412-20, 4812 & 4812-20 Switching Regulated Converter
Designed for FM transceivers and other applications requiring 12-volt power
source converted from 24-volt positive ground battery. Regulated with pulse
width modulation at 20 KHz.
2412 2412-20 4812 4812-20
Input (Negative ground only) 22-32V DC 22-32V DC 30-56V DC 30-56V DC
Output Voltage (±.2V DC) 13.8V DC 13.8V DC 13.8V DC 13.8V DC
Line/Load Regulation 200mV 200mV 200mV 200mV
Ripple Noise 50mV RMS 50mV RMS 50mV RMS 50mV RMS
Current Continuous 9 Amp 16 Amp 9 Amp 16 Amp
Current Limit 12 Amp 20 Amp 12 Amp 20 Amp
2412/4812 Case Size 2 3/4(H) x 6(W) x 6(D)
2412-20/4812-20 Case Size 2 3/4(H) x 6(W) x 12(D)
Shipping Weight 2 lbs. 3 lbs. 2 lbs. 3 lbs.
|
|||||||
![]() |
MODEL 12-115
Solid State Power Inverter, 200W.
Parallel connection for higher power up to 350W
Covert 12 volts DC to 115 volts AC @ 60 Hz output. 200 watts continuous operation
with peak power up to 240 watts. All silicon semiconductors assure high reliability
at excessive ambient temperatures. The output voltage is square wave. The inverter
is not recommended where high transients are not tolerable.
The 12-115 allows you to have AC house current in your boat, car, truck, camper,
house trailer or house boat. Will operate small household appliances, T.V., hand
tools, electric shaver, AC radios and lights within the power rating. Built-in
overload prtection.
12V DC IN 14V DC IN
Output Voltage (No Load) 115 V RMS 130 V RMS
Output Voltage (Full Load) 110 V RMS 115 V RMS
Frequency (No Load) 58 Hz 66 Hz
Frequency (Full Load) 54 Hz 62 Hz
Power Continuous 200W. Parallel connection (2 units) 350W
Case: 4 1/2"(H) x 8"(W) x 9"(D). Shipping Weight: 9 lbs.
|
|||||||
![]() |
MODEL 12V4 Converts 115 volts AC to 12 volts DC. Ideally suited for most applications including 8-track stereo, burglar alarm, car radio and cassette tape player. Continuous Current (Full Load) 1.75 Amp Output Voltage (No Load) 16 V max. Output Voltage (Full Load) 12 V min. Ripple (Full Load) .4 V RMS Short Circuit Protection Thermal Breaker Case: 3"(H) x 4"(W) x 5 1/4"(D) Shipping Weight: 9 lbs. |
|||||||